General Purpose SingleAxis Accelerometers

General Purpose

Accelerometers

The single and triaxial ICP® accelerometers are designed with a low temperature coefficient, wide operating temperature range, and good broadband measurement resolution, making them ideal for any vibration measurement requiring tight control of amplitude sensitivity over a wide thermal gradient. To alleviate the effects of high frequency overloads caused by metal-to-metal inputs, a low pass filter has been incorporated in some models, ensuring accurate data in the frequency range of interest.

Single Axis Accelerometers Table
SINGLE AXIS ACCELEROMETERS – ESS / HALT / HASS
Model Number 320C03 320C04 320C15 320C20 320C33 320C52 320C53
Sensitivity 10 mV/g 10 mV/g 10 mV/g 10 mV/g 100 mV/g 10 mV/g 1 mV/g
Measurement Range ± 500 g pk ± 500 g pk ± 500 g pk ± 500 g pk ± 50 g pk ± 500 g pk ± 5,000 g pk
Frequency Range (±5%) 1 to 6,000 Hz 1 to 10,000 Hz 2 to 5,000 Hz 1 to 4,000 Hz 1 to 10,000 Hz 1 to 5,000 Hz
Operating Temperature Range -100 to +325 °F (-73 to +163 °C)
Sensing Element Quartz UHT-12™
Optional Models - J Isolation / M Metric J320C03 J320C04 M320C15 M320C20 --- M320C52 M320C53
Typical Applications Accelerated life and durability testing at elevated temperatures
Single Axis Accelerometers (Ceramic) Table
SINGLE AXIS ACCELEROMETERS (CERAMIC) – GENERAL PURPOSE
Model Number 352B01 352C03 352C04 352B10 352C33 352C34 352C41
Sensitivity 1 mV/g 10 mV/g 100 mV/g 10 mV/g
Measurement Range ± 5000 g pk ± 500 g pk ± 50 g pk ± 500 g pk
Frequency Range (±5%) 2 to 10,000 Hz 0.5 to 10,000 Hz 2 to 10,000 Hz 0.5 to 10,000 Hz 1 to 9,000 Hz
Weight 0.03 oz [0.7 gm] 0.2 oz [5.8 gm] 0.03 oz [0.7 gm] 0.2 oz [5.8 gm] 0.1 oz [2.8 gm]
Optional Models - Metric Mounting --- Included --- Included ---
Optional Models - TEDS --- TLD352C03 TLD352C04 --- TLD352C33 TLD352C34 ---
Optional Models - Ground Isolation --- J352C03 J352C04 --- J352C33 J352C34 ---
Typical Applications General vibration testing of small components or within devices where mass is a concern
Single Axis Accelerometers (Quartz) Table
SINGLE AXIS ACCELEROMETERS (QUARTZ) – GENERAL PURPOSE
Model Number 353B03 353B04 353B11 353B14 353B15 353B16
Sensitivity 10 mV/g 5 mV/g 10 mV/g
Measurement Range ± 500 g pk ± 1,000 g pk ± 500 g pk
Frequency Range (±5%) 1 to 7,000 Hz 1 to 10,000 Hz
Weight 0.38 oz [10.5 gm] 0.07 oz [2.0 gm] 0.06 oz [1.8 gm] 0.07 oz [2.0 gm] 0.05 oz [1.5 gm]
Optional Models -
Metric Mounting
Included Included M353B11 M353B14 M353B15 M353B16
Optional Models -
Ground Isolation
J353B03 J353B04 --- J353B14 J353B15 J353B16
Typical Applications Low-noise application where overload or thermal shock may be an issue; maintains high stability through thermal cycling.
Single Axis Ring Accelerometers Table
SINGLE AXIS RING ACCELEROMETERS WITH ISOLATION
Model Number 355B02 355B03 355A44 7250B-10 7251A-10 7251A-100
Sensitivity 10 mV/g 100 mV/g 10 mV/g 10 mV/g 10 mV/g 100 mV/g
Measurement Range ± 500 g pk ± 50 g pk ± 500 g pk ± 500 g pk ± 500 g pk ± 50 g pk
Frequency Range (±5%) 1 to 10,000 Hz 1 to 5,500 Hz 3 to 20,000 Hz 2 to 10,000 Hz (±10%)
Isolation Method Ground Isolated Case Isolated Ground Isolated
Optional Models - Metric Mounting M355B02 M355B03 --- --- --- ---
Typical Applications A wide variety of applications from durability testing to active monitoring of harmonics
Triaxial Thru-Bolt Accelerometers Table
TRIAXIAL THRU-BOLT ACCELEROMETERS WITH ISOLATION
Model Number 354C02 354C03 354B04 354B05 354C10
Sensitivity 10 mV/g 100 mV/g 10 mV/g 100 mV/g 10 mV/g
Measurement Range ± 500 g pk ± 50 g pk ± 500 g pk ± 50 g pk ± 500 g pk
Frequency Range (±5%) 0.5 to 2,000 Hz 0.6 to 10,000 Hz 2 to 8,000 Hz
Isolation Method Ground Isolated Case Isolated Ground Isolated
Optional Models - Metric Mounting M354C02 M354C03 Included Included M354C10
Optional Models - TEDS TLD354C02 TLD354C03 Included Included ---
Typical Applications Structural analysis with low noise in applications with electromagnetic field interference
Triaxial Accelerometers Table
TRIAXIAL ACCELEROMETERS
Model Number 356A02 356A14 356A15 356A16 356A17
Sensitivity 10 mV/g 100 mV/g 500 mV/g
Measurement Range ± 500 g pk ± 50 g pk ± 10 g pk
Frequency Range (±5%) 1 to 5,000 Hz 0.5 to 5,000 Hz 2 to 5,000 Hz 0.5 to 5,000 Hz 0.5 to 3,000 Hz
Weight 0.37 oz [10.5 gm] 0.26 oz [7.4 gm] 0.33 oz [9.3 gm]
Optional Models - TEDS TLD356A02 TLD356A14 TLD356A15 TLD356A16 TLD356A17
Optional Models - High Temperature HT356A02 --- HT356A15 --- ---
Typical Applications General purpose, modal analysis, or vibration feedback

Need Help? Let’s Talk!

Have questions or need support? Our team is here to assist you. Reach out now!